Sign In
Labcorp Oklahoma, Inc.
Test Directory


Index:

Anti-PLA2R

Order Name Anti-PLA2R
Test Number: 5194915
Revision Date 12/12/2022
Test Name Methodology LOINC Code
Anti-PLA2R
Enzyme-Linked Immunosorbent Assay (ELISA)  
SPECIMEN REQUIREMENTS
Specimen Specimen Volume (min) Specimen Type Specimen Container Transport Environment
Preferred 0.5 mL (0.2 mL) Serum Clot Activator SST Room Temperature
Instructions Notes: 0.2 mL (Note: This volume Does NOT allow for repeat testing.)
Specimen Type: Red-top tube or gel-barrier tube
Specimen Storage: Room temperature
Specimen Collection: If a red-top tube is used, transfer separated serum to a plastic transport tube.
Specimen Stability: Ambient: 14 days, Refrigerated : 14 days, Frozen: 14 days
GENERAL INFORMATION
Expected TAT 2 - 8 days  
Performing Labcorp Test Code 141330 
Notes Labcorp Test Code: 141330
CPT Code(s) 83516
Lab Section Reference Lab