Aluminum, Random Urine

Order Name ALUMINUM U
Test Number: 2001500
Revision Date 12/10/2022
Test Name Methodology LOINC Code
Aluminum, Random Urine
Inductively-Coupled Plasma/Mass Spectrometry  
SPECIMEN REQUIREMENTS
Specimen Specimen Volume (min) Specimen Type Specimen Container Transport Environment
Preferred 5 mL (1.5 mL) Urine, Random Acid Washed, Trace Element Free Contatiner Room Temperature
Instructions Specimen Type: Plastic urine container, no preservative
Specimen Storage: Maintain specimen at room temperature.
Specimen Collection: OPTIONAL PROTOCOL: Instruct the patient to void at 8 AM and discard the specimen. Then collect all urine including the final specimen voided at the end of the 24-hour collection period (ie, 8 AM the next morning). Avoid contact with metal during collection. Screw the lid on securely.
Special Instructions: Do not use preservatives. Preservatives used for routine analysis may contain mercuric oxide (ie, Stabilur), which interferes with all metal testing. If both urinalysis and metal testing are ordered, please submit a separate urine specimen (containing no
Specimen Stability: Ambient: 14 days, Refrigerated : 14 days, Frozen: 14 days
GENERAL INFORMATION
Expected TAT 2-4 Days  
Performing Labcorp Test Code 071555 
Notes Labcorp Test Code: 071555
CPT Code(s) 82570, 82108
Lab Section Reference Lab