Tocainide Level

Order Name TOCAINIDE
Test Number: 3611150
Revision Date 12/12/2022
Test Name Methodology LOINC Code
Tocainide Level
Liquid Chromatography/Tandem Mass Spectrometry  
SPECIMEN REQUIREMENTS
Specimen Specimen Volume (min) Specimen Type Specimen Container Transport Environment
Preferred 1 mL (0.5 mL) Serum Clot Activator (Red Top, No-Gel) Room Temperature
Alternate 1 1 mL (0.5 mL) Plasma Lithium Heparin (Dark Green Top / No-Gel) Room Temperature
Alternate 2 1 mL (0.5 mL) Plasma EDTA (Lavender Top) Room Temperature
Instructions Specimen Type: Red-top tube OR green-top (heparin) tube. Gel-barrier tubes are NOT recommended.
Specimen Storage: SUBMISSION/TRANSPORT (<3 days): Room Temperature. For storage beyond three days, specimen should be refrigerated or frozen.
Specimen Collection: Serum or plasma should be separated from cells within two hours of venipuncture. Submit serum or plasma in a plastic transport tube.
Special Instructions: Testing referred to MedTox Laboratories Inc tc 121
GENERAL INFORMATION
Expected TAT 5 - 7 days  
Performing Labcorp Test Code 811372 
Notes Labcorp Test Code: 811372
CPT Code(s) 80299
Lab Section Reference Lab