Hantavirus Antibody IgG and IgM
Order Name
HANTA PULM
Test Number: 3660775
Revision Date 12/12/2022
Test Number: 3660775
Revision Date 12/12/2022
Test Name | Methodology | LOINC Code |
---|---|---|
Hantavirus IgG
|
Enzyme-Linked Immunosorbent Assay (ELISA) | 35392-0 |
Hantavirus IgM
|
Enzyme-Linked Immunosorbent Assay (ELISA) | 35393-8 |
SPECIMEN REQUIREMENTS | ||||
---|---|---|---|---|
Specimen | Specimen Volume (min) | Specimen Type | Specimen Container | Transport Environment |
Preferred | 0.5 mL (0.1 mL) | Serum | Clot Activator SST | Refrigerated |
Instructions | Specimen Type: Red-top tube or gel-barrier tube Specimen Storage: Maintain specimen at room temperature. Stability: Room Temperature: 7 days Special Instructions: Testing referred to Quest Diagnostics Infectious Disease TC 37547 Specimen Stability: Ambient: 5 days, Refrigerated : 14 days, Frozen: 30 days |
GENERAL INFORMATION | |
---|---|
Testing Schedule | Mon, Wed, Sat |
Expected TAT | 3 days from setup |
Notes | Labcorp Test Code: 835027 |
CPT Code(s) | 86790x2 |
Internal Comments | 10/26/17 removed this text - JK Effective 01/30/2017 This test will no longer reflex to Sin Nombre virus IgG/IgM titers 5/24/18 JK updated :1) Decrease the specimen volume from 1mL (0.25mL) to new 0.5mL (0.1mL) 2) RT stability changes from 5 days to 7 days. RF & FZ will remain at 14 days & 30 days, respectfully. 3) Testing schedule changing from M-Sat to Mon, Wed, Sat. TAT is still -3 days from set-up. |
Lab Section | Reference Lab |