Estrogens Fractionated
Order Name
ESTROG FRA
Test Number: 3618875
Revision Date 02/22/2023
Test Number: 3618875
Revision Date 02/22/2023
Test Name | Methodology | LOINC Code |
---|---|---|
Estrogens Fractionated
|
Liquid Chromatography/Mass Spectroscopy |
SPECIMEN REQUIREMENTS | ||||
---|---|---|---|---|
Specimen | Specimen Volume (min) | Specimen Type | Specimen Container | Transport Environment |
Preferred | 2.6 mL (1.3 mL) | Serum | Clot Activator SST | Refrigerated |
Instructions | Gel-barrier serum separator tube. Red top tubes (without gel barrier) should not be used. 1.3 mL (NOTE:This volume does NOT allow for repeat testing.) |
GENERAL INFORMATION | |
---|---|
Expected TAT | Report available: 1-4 days from set up at performing lab |
Clinical Use | Estriol Level Estradiol Ultra Sensitive Estrone Level |
Notes | Labcorp Test Code: 146068 |
CPT Code(s) | 82677, 82679, 82670 |
Internal Comments | 10/18/17 ad link JK 12/10/18: Added hemolysed specimen as unacceptable - SN 2/19/2020 changed stability from Specimen Stability Room temperature: 48 hours Refrigerated: 7 days Frozen -20° C: 2 years Frozen -70° C: 3 years to Specimen Stability Room temperature: 5 days, Refrigerated: 7 days, Frozen 28 days. 09/23/20: Updated CPT |
Lab Section | Reference Lab |