Selenium, Serum/Plasma
Order Name
SELENIUM
Test Number: 3610600
Revision Date 02/07/2023
Test Number: 3610600
Revision Date 02/07/2023
| Test Name | Methodology | LOINC Code |
|---|---|---|
|
Selenium, Serum/Plasma
|
Inductively-Coupled Plasma/Mass Spectrometry |
| SPECIMEN REQUIREMENTS | ||||
|---|---|---|---|---|
| Specimen | Specimen Volume (min) | Specimen Type | Specimen Container | Transport Environment |
| Preferred | 2 mL (0.6 mL) | Serum | Royal Blue - No Additive Clot (Trace Element Free) | Room Temperature |
| Alternate 1 | 2 mL (0.6 mL) | Plasma | Royal Blue - EDTA (Trace Element Free) | Room Temperature |
| Instructions | Specimen: Serum or Plasma Notes: 0.6 mL (Note: This volume Does NOT allow for repeat testing). Specimen Type: Royal blue-top Clot Tube OR Royal Blue-top (EDTA) tube Specimen Storage: Maintain specimen at room temperature. Specimen Collection: Separate serum or plasma immediately after the collection, and transfer to a certified metal-free transport tube (PeopleSoft No. 111166) for shipment to the laboratory. Specimen Stability: Ambient: 14 days, Refrigerated : 14 days, Frozen: 14 days |
|||
| GENERAL INFORMATION | |
|---|---|
| Expected TAT | 2 - 4 days one working day. |
| Notes | Labcorp Test Code: 716910 |
| CPT Code(s) | 84255 |
| Internal Comments | 05/20/19: Updated TAT and setup; see TQM 2071 02/18/20 Updated instructions - SN |
| Lab Section | Reference Lab |